Loading... Loading...
English
French

DENCO Technologies

DENCO TECHNOLOGIES - 104, rue Bellocier - 89107 SENS CEDEX - France

Especially intended to technical premises using "plenum" as a ventilation area.

The ventilation

DESCRIPTION

Composition
Nominal standard size 600 x 600 mm
Top steel plate with 2850 perforations dia. 6 mm (1), providing a free cross sectional area of 800 cm².
Welded steel frame and reinforcements
The set is treated against the corrosion.
Visible Black PVC edge trim crimped to the top plate, 5 mm wide
Factory bonded selected floor covering.
Exists in 30 or 38 mm thick.

PERFORMANCES

Fire rating
The structure of SEC 800 panel is M0 by nature

Electrostatic properties
Depending of the quality and the conception of the covering, vary from 5 x 105
to 2 x 1012 ohms according to standard NFP 62001

Point loads

 
SEC 800.30 or 38
 
Understructure
Covering
Stringerless
Lockable
Laminate
3A (3B or 3C)
3A (5B or 5C)

Load classes according to norm NF EN 12825
Safety factor = 2

OPTIONS

To regulate the air flow :
a damper (adjustable without removing panel) consisting of two corrosion protected perforated steel sheets, one fixe, the other sliding.

COVERINGS

The SEC 800 panel can be supplied with the following coverings :
laminate, vinyl, linoleum (textile excluded)

SEC 800 perforated
NB : A system classed 1A is a system which the ultimate load is at least 4 kN (load classe 1). The working load is at least 2 kN, with a safety factor of 2, for a deflection less than 2,5 mm (deflection class A).
See tables below for the other classes
 
Class
Class
Class
Class
Class
Class
Deflection class
Maximum deflection
Load class
1
2
3
4
5
6
A (the more stringent)
2,5 mm
Class break
> 4 kN
> 6 kN
> 8 kN
> 9 kN
> 10 kN
> 12 kN
B
3 mm
Working class
> 2 kN
> 3 kN
> 4 kN
> 4,5 kN
> 5 kN
> 6 kN
C (the less stringent)
4 mm
incombustible
-
Syndicat National de l’Isolation
-

fire security

-
Data Center
-

static electricity dissipating gasket

-
massive parquet
-

COMPACT 30/M0 and 25/M0 panels

-

BRACE SYSTEM

-
Covering linoleum
-

Railing of ventilation

-

Top face varnished

-
Covering vinyl
-

Stability

-
Wooden strips
-

OE

-
Reconstituted stone
-

DALU 38.2

-
Covering rubber
-

telephonic exchanges

-

EUROBAC 38.5

-
Covering laminate
-

Steps

-
Fédération Française du Bâtiment
-

European norm NF EN 12825

-
Top corrosion protected steel skin 0,5 mm
-

VGH

-
Steps
-

Pedestals for low floors

-
Covering linoleum
-
Welded steel frame
-

Passage of cables or electric box

-
raised access floors installation
-

Special understructure meshing

-

Special for heavy loads

-
Suction lifters
-
David
-

DALU panel

-

Covering granit

-
Electric conductivity of the system
-

Easy to carrier

-
Partitions stop fire